Italcementi - Calusco 
EMISSIONI NUOVA LINEA DI COTTURA 
Analisi Valori Medi 

  [Mese Precedente]    [Mese Successivo]    [Principale]

 

Mensile lineare 09/2020
 
 
DustHunter Polvere 
secco @ rif.O2 
- convalidato 
mg/Nm3
 
SO2 secco @ rif.O2 
- convalidato 
 
mg/Nm3
 
NOx secco @ rif.O2 
- convalidato 
 
mg/Nm3
 
CO secco @ rif.O2 
- convalidato 
 
mg/Nm3
 
HCl secco @ rif.O2 
- convalidato 
 
mg/Nm3
 
NH3 secco @ rif.O2 
- convalidato 
 
mg/Nm3
 
TOC (come C) secco 
@ rif.O2 - convalidato 
 
mg/Nm3
01/09/2020 1.7 4.2 410.0 446.3 0.2 4.7 43.5
02/09/2020 1.6 16.9 383.4 516.3 0.3 5.0 36.1
03/09/2020 1.7 20.2 331.0 535.0 0.3 2.9 31.0
04/09/2020 1.7 29.9 321.3 289.2 0.3 1.7 31.8
05/09/2020 1.8 43.8 396.5 233.0 0.4 2.2 29.7
06/09/2020 1.9 46.6 396.6 262.7 0.5 1.2 28.3
07/09/2020 1.9 40.8 386.6 252.3 0.4 1.7 32.7
08/09/2020 1.7 38.1 412.0 168.4 0.8 1.6 29.7
09/09/2020 1.7 5.4 356.1 127.6 0.6 1.2 29.7
10/09/2020 2.0 5.5 380.2 132.6 0.6 1.2 35.5
11/09/2020 1.5 28.1 378.6 288.1 1.4 15.1 42.6
12/09/2020    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.    N.A.
13/09/2020 1.3 32.4 366.8 543.3 2.9 1.2 41.6
14/09/2020 1.6 30.1 411.7 371.1 1.4 1.2 34.5
15/09/2020 2.0 21.4 399.7 593.2 0.7 16.9 45.0
16/09/2020 1.7 22.1 404.7 573.4 0.4 1.2 40.0
17/09/2020 1.7 24.3 372.0 414.4 1.1 6.7 34.8
18/09/2020 1.7 18.7 373.3 385.8 1.2 1.9 39.4
19/09/2020 1.9 34.0 394.8 362.1 0.8 6.4 38.4
20/09/2020 1.8 13.7 313.2 194.5 0.4 5.1 36.6
21/09/2020 1.7 13.6 368.8 424.9 0.4 4.4 40.8
22/09/2020 2.2 24.2 393.3 447.0 0.5 20.7 42.9
23/09/2020 1.8 23.5 409.2 437.6 0.3 4.9 43.2
24/09/2020 2.0 36.2 392.4 427.9 0.5 9.6 44.6
25/09/2020 2.1 25.4 404.0 362.5 0.4 8.3 44.2
26/09/2020 2.2 15.3 407.5 332.8 0.3 5.2 46.3
27/09/2020 2.3 25.6 393.1 363.8 0.6 7.9 44.5
28/09/2020 2.6 27.8 423.0 188.8 0.7 8.5 48.5
29/09/2020 2.2 33.3 414.2 165.7 0.8 9.9 40.5
30/09/2020 2.0 17.2 409.5 287.8 0.5 3.5 38.2
  
SemiOre valide 1174 1174 1174 1174 1174 1174 1174
SemiOre N.F. 1176 1176 1176 1176 1176 1176 1176
  

  [Mese Precedente]    [Mese Successivo]    [Principale]    [Esportazione]


Legenda MESE

N.D. = Non Disponibile      OFF = Sistema non attivo      Tar = Calibrazione 
* = Non Valido      MAN = Manutenzione      NVA = Soglie Validazione 
ERR = Anomalie      AUX = Alternativa      F = Minimo Tecnico non raggiunto 
N.A. = Non Applicabile(Minimo Tecnico)      > = Superamento soglia normativa V/L = Validi/Lavorati      N.F. = Normale funzionamento      m = Manuale 
I.F. = Impianto fermo      r = Ricalcolato      (alt) = Alternativo 

 

 

Italcementi - Calusco - 752-0190-02 